1352502482670 a43c0a0a8e0f1bff628f9d21993f1a76

CLAS Goldwater Environmental Laboratory (GEL)

Tempe, Arizona, US

The Goldwater Environmental Laboratory (GEL) is a shared-use facility available to all research staff, faculty, and students of all disciplines.

The facility encompasses seven laboratories and is part of the College of Liberal Arts and Sciences Research Technical Services group.

GEL staff are committed to providing the tools necessary to meet the analytical needs of researchers while creating a valuable educational experience for users.

Although most users perfer to receive individualized hands-on training enabling them to perform their own analyses, complete analytical services are also available.

CLAS Goldwater Environmental Laboratory (GEL) has not listed any services.

Ask A Question Find what you're looking for? If not, you can ask this lab a question:
Elemental Analysis
Price on request

he PE 2400 is a conventional elemental analyzer. It operates by flash combustion of the specimen encapsulated in tin cups or disks whereby the specimen is completely combusted at a temperature of 1760 C.

The resulting gases are chemically scrubbed of the halogens (and of sulfur in the CHN mode) and are separated in a GC... Show more »

he PE 2400 is a conventional elemental analyzer. It operates by flash combustion of the specimen encapsulated in tin cups or disks whereby the specimen is completely combusted at a temperature of 1760 C.

The resulting gases are chemically scrubbed of the halogens (and of sulfur in the CHN mode) and are separated in a GC column. Detection is conducted by a thermal conductivity detector (TCD). Total C, H, and N are calculated with a precision of 0.1g.

Element ratios are more significant since they minimize instrument error. Molar element ratios may be reliably reported for up to three decimal places.

« Show less
Flow Injection Analysis
Price on request

The QC 8000 determines analyte concentrations using colorimetry to detect changes in color produced by the presence of analytes. It is typically used for automated testing of water, waste water and sea water. It is capable of measuring a wide range of analytes, given the appropriate manifold configuration and filter.

Currently... Show more »

The QC 8000 determines analyte concentrations using colorimetry to detect changes in color produced by the presence of analytes. It is typically used for automated testing of water, waste water and sea water. It is capable of measuring a wide range of analytes, given the appropriate manifold configuration and filter.

Currently we are able to measure: Ammonia, Chloride, Nitrate, Nitrite, Orthophosphate, and Alkalinity (methyl orange as a function of CaCO3). It can be expanded to measure dozens of other analytes as well.

The instrument is equipped with a 360 position autosampler for multiple sample analysis and an autodilutor for dilution of off-scale samples. It is capable of processing a combination of two analytes simultaneously.

« Show less
GC-MS
Gas Chromatography Coupled Mass Spectrometry
Price on request

Gas Chromatography / Mass Spectrometry - HP Quadrupole

Comprised of an HP 5890 GC interfaced to a HP 5972 Mass Selective Detector Quadrupole Mass Spectrometer, the system uses electron impact (EI) ionization to produce mass fragmentation and is capable of performing full mass scans or selective ion monitoring (SIM) of one or... Show more »

Gas Chromatography / Mass Spectrometry - HP Quadrupole

Comprised of an HP 5890 GC interfaced to a HP 5972 Mass Selective Detector Quadrupole Mass Spectrometer, the system uses electron impact (EI) ionization to produce mass fragmentation and is capable of performing full mass scans or selective ion monitoring (SIM) of one or more specific masses.

The system is equipped with one split/splitless capillary injection port which will accommodate liquid, headspace, or SPME injections.

« Show less
ICP-AES/OES
Inductively Coupled Plasma Atomic Emission Spectroscopy/Optical Emission Spectroscopy
Price on request

The iCAP is capable of rapid, simultaneous measurement of up to 70 elements in aqueous and organic solutions and is equipped with an autosampler with a 240 sample capacity.

The dual view design offers the flexibility of axial view for lowest detection limits and radial view for reduced interference; ideal for complex samples... Show more »

The iCAP is capable of rapid, simultaneous measurement of up to 70 elements in aqueous and organic solutions and is equipped with an autosampler with a 240 sample capacity.

The dual view design offers the flexibility of axial view for lowest detection limits and radial view for reduced interference; ideal for complex samples often encountered in environmental research.

Full frame imaging produces a picture of a sample and can be a useful qualitative tool in determining sample composition. Detection limits vary by element but are typically in the low to sub-ppb (ug/L) level.

« Show less
Ion Exchange Chromatography
Price on request

Dionex ICS1000

This IC system determines analyte concentrations using chromatography columns and a pulsed electrochemical conductivity detector. It is typically used for automated testing of aqueous solutions. It is capable of measuring a wide variety of ions, given the appropriate eluant and analytical column. Currently, we... Show more »

Dionex ICS1000

This IC system determines analyte concentrations using chromatography columns and a pulsed electrochemical conductivity detector. It is typically used for automated testing of aqueous solutions. It is capable of measuring a wide variety of ions, given the appropriate eluant and analytical column. Currently, we are able to measure the major anions: Fluoride, Chloride, Bromide, Nitrate, Nitrite, Phosphate, and Sulfate as well as numerous other anions using an AS23 column. It can be reconfigured to analyze cations if required. The autosampler will accommodate up to 66 vials of 5 mL size, 88 vials of 0.5 mL size, or a combination of the two sizes.

Dionex ICS 2000
The ICS 2000 instrument is configured as a 2 mm system for high-sensitivity (sub-ppb) analysis. It is equipped with a potassium hydroxide eluent generator capable of gradient or stepped analysis and a column heater. These features offer improved peak resolution and sensitivity compared to the ICS 1000 system. Sample filtration via a 0.45 micron pore size filter (or smaller) is required.

« Show less
Microwave Processing
Price on request

Microwave Digestion System

This system can be used to digest or extract a wide variety of solid and liquid materials. Common applications include soils, minerals and rocks, sediments, sludges, plant and animal tissues, water, dairy. Commonly used to prepare samples for metals and nutrient (total N, P, S) analysis. Will accomodate 40 samples of 10-20 mL volume (including digestion reagents).

Microwave Digestion System

This system can be used to digest or extract a wide variety of solid and liquid materials. Common applications include soils, minerals and rocks, sediments, sludges, plant and animal tissues, water, dairy. Commonly used to prepare samples for metals and nutrient (total N, P, S) analysis. Will accomodate 40 samples of 10-20 mL volume (including digestion reagents).

« Show less
Porosity/Porosimetry Analysis
Price on request

The Tristar II 3020 provides high-quality surface area and porosity measurements on solid materials by using the technique of gas adsorption.

The TriStar II is a fully automated, three-station analyzer capable of increasing the speed and efficiency of quality control analyses, with the accuracy, resolution, and data reduction to meet most research requirements.

The Tristar II 3020 provides high-quality surface area and porosity measurements on solid materials by using the technique of gas adsorption.

The TriStar II is a fully automated, three-station analyzer capable of increasing the speed and efficiency of quality control analyses, with the accuracy, resolution, and data reduction to meet most research requirements.

« Show less
Total Organic Carbon and Nitrogen Analysis
Total organic carbon nitrogen analysis
Price on request

The Shimadzu TOC-VC/TN analyzes liquid samples for total carbon (TC), inorganic carbon (IC), total organic carbon (TOC), and non-purgeable organic carbon (NPOC).

The TN unit allows for simultaneous TOC and Total Nitrogen (TN) analysis. A known amount of sample is introduced into the instrument and is either combusted (TC, TOC,... Show more »

The Shimadzu TOC-VC/TN analyzes liquid samples for total carbon (TC), inorganic carbon (IC), total organic carbon (TOC), and non-purgeable organic carbon (NPOC).

The TN unit allows for simultaneous TOC and Total Nitrogen (TN) analysis. A known amount of sample is introduced into the instrument and is either combusted (TC, TOC, NPOC) or acidified and purged (IC).

Carbon content is measured as CO2 by non-dispersive infrared gas analysis. The TOC-VC combustion analyzer has a measuring range of 1mg C/L to 25,000mg C/L with reproducibility of 1.5% CV.

It has a wide range of applications from ultra pure water to highly contaminated water. It is capable of multiple standard level and multiple constituent analyses in a

« Show less
Discrete Chemical Analysis
Price on request

The AQ2 is a discrete analyzer that determines analyte concentrations using a colorimeter to detect changes in color produced by the presence of the analytes.

It is typically used for automated testing of water, waste water and sea water. It is capable of measuring a wide range of elements, given the appropriate flow cell,... Show more »

The AQ2 is a discrete analyzer that determines analyte concentrations using a colorimeter to detect changes in color produced by the presence of the analytes.

It is typically used for automated testing of water, waste water and sea water. It is capable of measuring a wide range of elements, given the appropriate flow cell, filter and manifold set-up. Currently we are able to measure: Ammonia, Chloride,Nitrogen (Nitrate, Nitrite, and Total Nitrogen), Phosphorus (ortho and total Phosphorus).

It is also currently capable of measuring acidity (thymol blue), alkalinity (methyl orange and thymol blue) and hardness of water as a function of CaCO3.

The instrument is equipped with an autosampler for multiple sample analysis. It can be expanded to allow performance other analyses if necessary.

« Show less
Imaging & Spectroscopy
Price on request
Request a quote for more information about this service.
Spectroscopy
Price on request
Request a quote for more information about this service.
Mass Spectrometry
Price on request
Request a quote for more information about this service.
Other Mass Spectrometry Methods
Price on request
Request a quote for more information about this service.
Atomic Emission Spectroscopy
Price on request
Request a quote for more information about this service.
Chemistry and Materials
Price on request
Request a quote for more information about this service.
Analytical Chemistry Services
Price on request
Request a quote for more information about this service.
Purification Services
Price on request
Request a quote for more information about this service.
Chromatography
Price on request
Request a quote for more information about this service.
Liquid Chromatography
Price on request
Request a quote for more information about this service.
Engineering and Fabrication
Price on request
Request a quote for more information about this service.
Fabrication and Materials Processing Services
Price on request
Request a quote for more information about this service.
Physical Analysis Methods
Price on request
Request a quote for more information about this service.

CLAS Goldwater Environmental Laboratory (GEL) has not received any ratings.

Be the first to endorse CLAS Goldwater Environmental Laboratory (GEL)